Computed Radiography
iCRco Computed Radiography
iCR3600 system - Computed Radiography

Computed Radiography

iCR 3600 System

Stay competitive. Improve patient care. Innovate imaging workflow.

The iCR3600 will transform your office into a modern imaging facility.  iCR3600 offers our patented True Flat Scan Path™ technology for exceptional image quality, high throughput, and low cost of ownership.  Ideal for private practice offices and imaging clinics, the iCR3600 will innovate your imaging workflow.

In addition, iCR3600 is the true meaning of an integrated solution.  It is paired with the superior image processing software Clarity Captera™.  With the robust and feature rich Clarity Captera, you get superior quality images every time with an option to further manipulate the images to the physician’s preference.

iCRco has been a leader in bringing you the most innovative technologies in medical imaging for almost 20 years.  Our flagship product is backed by a two year guarantee and is the true complete solution for your practice.

Downloads:

Download brochure pdf

icr3600

iCR3600 Specifications

Micron Spot Size
Pixels Per mm
Dots Per Inch (DPI)
Line Pairs Per mm
200
5
127
2.5
100
10
254
5
THE ICR3600 CAPTURES AT 15 MEGAPIXELS

 

Grayscale Resolution

16 bits/pixel source file, 65536 shades of gray

Image Access Time

35 seconds on 14” x 17” plates  (35.56 x 43.18 cm)

Plate Throughput

94 plates per hour with mixed cassette sizes

Cassette Sizes

14” x 17” (35.56 x 43.18 cm), 10” x 12” (25.40 x 30.48 cm),
8” x 10” (20.32 x 25.40 cm),  Odd plate sizes accepted and flexible plates scanned using glass cassette system

Weight

78 lbs (35 kg)

Dimensions

W44” x D12” x H23”  (W112 x D31 x H59 cm), Wall Mountable

Power Source

100-240V AC/ 2.5A max; 47-63Hz  (Universal Power Supply)

Heat Generation

Standby 230W, Maximum 1610W

Operating Conditions

Temperature; 0-40°C/32-105°F, Temperature change: 0.5°C/min, Humidity: 15%-95% RH, Magnetic Fields: max 1260 µT 
(in Conformance with EN 61000-4-8: Level 3), 10 A/m

* Specifications are subject to change without notice.  Processing and display time dependent on   processor speed, RAM disk access time, and video card.