Computed Radiography
iCRco Computed Radiography
iCR3600M system - Computed Radiography

Computed Radiography

iCR 3600M System

Stay competitive. Improve patient care. Innovate imaging workflow.

Women’s health has always been in the center of development efforts at iCRco. Many studies have established CR Mammography is as efficient as DR Mammography, and offered at a fraction of the cost while eliminating the need for replacing the existing X-ray room equipment. iCR3600M* integrates seamlessly into the existing workflow. iCR3600M* is affordable since it can also be used for all areas of general radiography with appropriate size cassettes. The ultra high resolution and precision of this CR makes it second to none.

It is paired with the superior image acquisition software Clarity Captera™ for further manipulation of the images, applying advanced image processing algorithms to look for even the smallest details. ICE-M, Image clarity enhancement algorithm, is specifically designed for mammography applications.

iCRco has been a leader in bringing you the most innovative technologies in medical imaging for almost twenty years

* Mammography not available in the USA or Canada

Downloads:

Download brochure pdf

iCR3600M

iCR3600M Specifications

Micron Spot Size
Pixels Per mm
Dots Per Inch (DPI)
Line Pairs Per mm
50
20
508
10
100
10
254
5
THE ICR3600M CAPTURES AT 60 MEGAPIXELS

 

Grayscale Resolution

16 bits/pixel source file, 65536 shades of gray

Plate Throughput

70 plates per hour

Cassette Sizes

14” x 17” (35 x 43 cm), 10” x 12” (25 x 30 cm), 8” x 10” (20 x 25 cm), High resolution mammography and odd plate sizes accepted.
Flexible plates scanned using glass cassette system.

Weight

78 lbs (35 kg)

Dimensions

W44” x D12” x H23”  (W112 x D31 x H59 cm), Wall Mountable

Power Source

100-240V AC/ 2.5A max; 47-63Hz  (Universal Power Supply)

Heat Generation

Standby 230W, Maximum 1610W

Operating Conditions

Temperature; 0-40°C/32-105°F, Temperature change: 0.5°C/min, Humidity: 15%-95% RH, Magnetic Fields: max 1260 µT 
(in Conformance with EN 61000-4-8: Level 3), 10 A/m

* Specifications are subject to change without notice.  Processing and display time dependent on   processor speed, RAM disk access time, and video card.

 

For further information regarding Computed Radiography, please call 01302 371500 or email information@danum.com.

Contact us today!

Complete our contact form or alternatively

information@danum.com or call +44(0)1302 371500

Tel: 0130 237 1500 - information@danum.com - Copyright © Danum International Limited - Internet Strategy by Lexiconnect Ltd